Emlid Caster — Connect Your RTK Base and Rover over the Internet

Emlid Caster is a cloud-based NTRIP relay that carries RTCM correction data from a compatible user-operated base to connected rovers over the internet. It does not generate corrections without an appropriate base station.

Technical content reviewed against official sources · 16 November 2026
Emlid Flow surveying software and coordinate management interface.
Emlid Flow coordinate and project workflow. Official manufacturer reference image.
WORKFLOW ARCHITECTURE01 — 04
01YOUR GNSS BASE
02NTRIP CASTER
03INTERNET LINK
04CONNECTED ROVERS

Observed data, configuration and quality evidence remain attached through handover.

Where Emlid Caster fits in the working system.

An NTRIP caster is a distribution point for correction streams. The base observes satellites and produces RTCM corrections; the caster receives that stream and makes it available to authorised rover connections; each rover then applies the corrections to its own GNSS observations.

This is different from a subscription correction network that operates reference infrastructure and provides correction services. With the free Emlid Caster workflow, the user supplies the base. Emlid Caster Pro is a separate paid enterprise offering combining caster/service functions and should not be confused with the free relay.

Every link has a separate configuration responsibility.

01 / Establish the base

Set a base-capable Reach receiver over a known point or determine its position appropriately. Configure RTCM3 correction output.

02 / Connect to the caster

Use the generated base connection details and internet access. Protect the mountpoint password and other credentials.

03 / Configure each rover

Enter the rover-side NTRIP details in Emlid Flow or the compatible client, connect mobile data and confirm correction input.

04 / Verify the observation

Check correction age, solution status, coordinates and a known point before relying on the rover for production measurements.

Know who operates the reference station.

Emlid Caster: Know who operates the reference station.
ArrangementReference sourceWhat the service doesUser responsibility
Emlid Caster free relayYour compatible baseRelays your base corrections to connected roversBase coordinate, base operation, links, rover setup and QA
Subscription NTRIP networkProvider-operated reference infrastructureSupplies correction data under subscription termsValid account, correct profile/mountpoint, connectivity and QA
Direct local radioYour compatible baseNo internet caster; radio carries correctionsCompatible radios, local operating requirements, base and rover setup
Emlid Caster ProConfirm the enterprise arrangementSeparate paid offering with caster/service functionsConfirm commercial and technical scope before specification

Plan for the connection to fail gracefully.

Internet at both ends

Base and rover require suitable internet connectivity for the caster route. Test bandwidth stability and field mobile coverage, not only office Wi-Fi.

Correct base position

A relay cannot repair an incorrect base coordinate. Absolute project accuracy is tied to the reference position and height handling.

Credential handling

Keep NTRIP passwords and tokens in approved operational storage. Never include them in general website enquiries or public screenshots.

Interruption procedure

Define what operators do when corrections stop: pause critical observations, inspect solution status, reconnect and recheck known control.

Share one base stream within documented limits.

Current free-caster limits
Current Emlid documentation lists up to five bases and ten simultaneously connected rovers. Confirm the current limits before designing a larger deployment.
Independent rover settings
Each rover still needs its own receiver configuration, antenna height, coordinate project and observation checks.
Team procedure
Use named mountpoints and controlled credentials, with clear ownership of base startup, shutdown and incident response.
Scaling beyond the free relay
Assess enterprise, service-level, administration and operational requirements rather than assuming a free caster is a managed correction network.

Choose between your base and SiReNT deliberately.

A local base/caster arrangement can suit repeated work on a controlled site or locations where an independent reference is preferred. SiReNT can remove the need to deploy your own base where the subscription, coverage and project method are suitable. Both require known-point validation and good survey practice.

Easepect can demonstrate base output, caster connection, rover input and interruption checks using representative equipment. Credentials are configured through the approved operational channel, not collected through the website form.

Before choosing Emlid Caster.

Not in the free base-to-rover relay workflow. It transfers RTCM corrections generated by your compatible base. Without that base stream, the free caster does not provide a correction network by itself.

Not sure which Emlid receiver suits your project?

Tell us what you are surveying, your operating environment and required deliverables. Model selection is optional; Easepect can help identify a suitable hardware and software workflow.